Chapter 8 Parameters ASDA-M
8-96 Revision December, 2014
Format:
DEC
Settings:
0: Disable all functions described below
1: Force to Servo On the software
2~4: (reserved)
5: This setting allows the written parameters not retain after the
power off. When the data is no need to save, it can avoid the
parameters continuously writing into the EEPROM and
shortening the lifetime of EEPROM.
Setting this parameter is a must when using communication
control.
6: In simulation mode (command simulation), the external Servo
On signal cannot work and DSP Error (variable 0x6F) is
regarded as 0. Parameter P0-01 only shows the external Error
(positive/negative limit, emergency stop, etc)
In this status, DO.SRDY is ON. Command is accepted in each
mode and can be observed via scope software. However, the
motor will not operate. The aim is to examine the command
accuracy.
7: High-speed oscilloscope, disable Time-Out function (It is for PC
software)
8: Back up all parameters (current value) and save in EEPROM.
The value still exists when re-power on.
The panel displays ‘to.rom’ during execution. (It can be
executed when Servo ON.)
-1,-5,-6,-7: Individually disable the function of 1,5,6,7
-2~-4, -8: (reserved)
NOTE
1) Please set the value to 0 in normal operation. The value
returns to 0 automatically after re-power on.
P2-31 AUT1
Speed Loop Frequency Response
Setting in Auto and Semi-auto Mode
Address: 023EH
023FH
Parameter
Attribute:
Parameter for individual axis
Related Section:
Section 5.6
Section 6.3.6
Operational
Interface:
Panel / Software Communication
Default:
80
Control
Mode:
ALL
Unit:
Hz
Range:
1 ~ 0x1000
Data Size:
16bit