Chapter 8 Parameters ASDA-M
8-138 Revision December, 2014
Settings:
Manually adjust the hardware offset. The adjustment function
needs to be enabled by the setting of parameter P2-08. It is not
suggested to adjust the auxiliary adjustment. This parameter
cannot be reset.
P4-18 COF4
Current Detector (W2 Phase) Offset
Adjustment
Address: 0424H
0425H
Parameter
Attribute:
Parameter for individual axis
Related Section: -
Operational
Interface:
Panel / Software Communication
Default:
Factory default
Control
Mode:
ALL
Unit:
-
Range:
0 ~ 32767
Data Size:
16bit
Format:
DEC
Settings:
Manually adjust the hardware offset. The adjustment function
needs to be enabled by the setting of parameter P2-08. It is not
suggested to adjust the auxiliary adjustment. This parameter
cannot be reset.
P4-19 TIGB
IGBT NTC Adjustment Detection Level
(cannot reset)
Address: 0426H
0427H
Parameter
Attribute:
Parameter for individual axis
Related Section: -
Operational
Interface:
Panel / Software Communication
Default:
Factory default
Control
Mode:
ALL
Unit:
-
Range:
1 ~ 4
Data Size:
16bit
Format:
DEC
Settings:
Please cool down the drive to 25 Celsius degree when adjusting