Chapter 8 Parameters ASDA-M
8-170 Revision December, 2014
P5-56 CMST
COMPARE - Start Address of Data
Array
Address: 0570H
0571H
Parameter
Attribute
Parameter for individual axis
Related Section:
Section 7.11.2
Operational
Interface
Panel / Software Communication
Default
0
Control
Mode
ALL
Unit
-
Range
0 ~ (The value of P5-10 minus 1)
Data Size
16bit
Format
DEC
Settings
The first COMPARE data is saved in the address of data array.
NOTE
It is writable only when COMPARE stops (please refer to P5-59)
P5-57
CMAX COMPARE - Axis Position
Address: 0572H
0573H
Parameter
Attribute
Parameter for individual axis
Related Section:
Section 7.11.2
Operational
Interface
Panel / Software Communication
Default
0
Control
Mode
ALL
Unit
-
Range
-2147483648 ~ +2147483647
Data Size
32bit
Format
DEC
Settings
The axis position of COMPARE pulse source is displayed here.
It is writable only when COMPARE stops (please refer to P5-59)