Chapter 8 Parameters ASDA-M
8-170 Revision December, 2014
P5-56 CMST
COMPARE - Start Address of Data
Array
Address: 0570H
0571H
Parameter
Attribute:
Parameter for individual axis
Related Section:
Section 7.11.2
Operational
Interface:
Panel / Software Communication
Default:
0
Control
Mode:
ALL
Unit:
-
Range:
0 ~ (The value of P5-10 minus 1)
Data Size:
16bit
Format:
DEC
Settings:
The first COMPARE data is saved in the address of data array.
NOTE
It is writable only when COMPARE stops (please refer to P5-59)
P5-57■
CMAX COMPARE - Axis Position
Address: 0572H
0573H
Parameter
Attribute:
Parameter for individual axis
Related Section:
Section 7.11.2
Operational
Interface:
Panel / Software Communication
Default:
0
Control
Mode:
ALL
Unit:
-
Range:
-2147483648 ~ +2147483647
Data Size:
32bit
Format:
DEC
Settings:
The axis position of COMPARE pulse source is displayed here.
It is writable only when COMPARE stops (please refer to P5-59)