Chapter 8 Parameters ASDA-A2
8-80 Revision February, 2017
Unit
%
Range
0 ~ 300
Data Size
16-bit
Format
Decimal
Settings
Setup protection level (for the percentage of rated torque, set the value
to 0 means to disable the function, set the value to 1 or number above
means to enable the function)
P1-58 CRSHT Motor Crash Protection Time
Address: 0174H
0175H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
1
Control
Mode
ALL
Unit
ms
Range
0 ~ 1000
Data Size
16-bit
Format
Decimal
Settings
Setup the protection time:
When it reaches the level, AL.030 occurs after exceeding the
protection time.
NOTE
This function is only suitable for non-contactable application, such as
electric discharge machines. (Please setup P1-37 correctly).
P1-59 MFLT Analog Speed Command
Address: 0176H
0177H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
0.0 0
Control
Mode
S
Unit
1 ms 0.1 ms
Range
0.0 ~ 4.0 0 ~ 40
Data Size
16-bit
Format
One decimal DEC