ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-153
Range
0 ~ 6
Data Size
16-bit
Format
Decimal
Settings
0: reserved
1: Execute the adjustment of analog speed input offset
2: Execute the adjustment of analog torque input offset
3: Execute the adjustment of current detector (V phase) hardware
offset
4: Execute the adjustment of current detector (W phase) hardware
offset
5: Execute the adjustment of 1~4 hardware offset
6: Execute the adjustment of IGBT ADC
NOTE
The adjustment function needs to be enabled by the setting of
parameter P2-08. When adjusting, the external wiring which connects
to analog speed or torque needs to be removed completely and must
be in Servo Off status.
P4-11 SOF1 Analog Speed Input Offset Adjustment 1
Address: 0416H
0417H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
Factory default
Control
Mode
ALL
Unit
-
Range
0 ~ 32767
Data Size
16-bit
Format
Decimal
Settings
Manually adjust the hardware offset. The adjustment function needs to
be enabled by the setting of parameter P2-08. It is not suggested to
adjust the auxiliary adjustment. This parameter cannot be reset.