Chapter 8 Parameters ASDA-A2
8-154 Revision February, 2017
P4-12 SOF2 Analog Speed Input Offset Adjustment 2
Address: 0418H
0419H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
Factory default
Control
Mode
ALL
Unit
-
Range
0 ~ 32767
Data Size
16-bit
Format
Decimal
Settings
Manually adjust the hardware offset. The adjustment function needs to
be enabled by the setting of parameter P2-08. It is not suggested to
adjust the auxiliary adjustment. This parameter cannot be reset.
P4-13 TOF1 Analog Torque Input Offset Adjustment 1
Address: 041AH
041BH
Operational
Interface
Panel / Software Communication
Related Section: -
Default
Factory default
Control
Mode
ALL
Unit
-
Range
0 ~ 32767
Data Size
16-bit
Format
Decimal
Settings
Manually adjust the hardware offset. The adjustment function needs to
be enabled by the setting of parameter P2-08. It is not suggested to
adjust the auxiliary adjustment. This parameter cannot be reset.