Refer to Figures 3-4 to Figure 3-7.
1. Ensure the surface to which the unit is to be mounted is sufficiently strong
enough to carry the weight of inverter.
2. Orient the wall bracket (Figure 3-4) horizontally (perpendicular to the floor).
3. Secure the mounting bracket on the wall with 12 M6 screws.
4. Hang the inverter on the wall mounting bracket.
5. Secure the inverter by 2 M5 screws on the position* shown as Figure 3-5.
* These are also grounding points for equipment grounding. (To ground the
inverter, please refer to Section 3.5)
3.2 Vertical wall mount
- The mounting bracket provided with the unit is specially designed and is the only
certified mounting device for mounting the inverter.
- Secure the mounting bracket on the wall with at least 8 M6 screws.
- Failure to comply with following mounting instructions including permitted
orientations and designated clearances may result in derated power output
and may void the warranty.
CAUTION !
Figure 3-3: Inverter dimensions
520 mm
490 mm
651 mm 220 mm
19
Installation