M42U
M36U
M28U
Operation and Installation Manual
Grid-tie Transformerless Solar Inverter
The power behind competitiveness
www.deltaww.com

Table of Contents

Questions and Answers

  • P
    Phillip FloydSep 12, 2025
    What does HW DSP ADC3 (F17) error mean on my Delta M42U?
    • J
      jacksontamaraSep 12, 2025
      If your Delta Inverter displays 'HW DSP ADC3 (F17)', the issue might be: 1. Insufficient input power, so check the input voltage, which must be >150Vdc. 2. Auxiliary power circuitry malfunction, so check the auxiliary circuitry inside the inverter. 3. A detection circuit malfunction, and you should contact customer service for technical support.
  • A
    Amanda LynchAug 25, 2025
    What should I do if my Delta M42U Inverter displays AC Volt Low (E10, E15, E20)?
    • P
      Patrick LivingstonAug 25, 2025
      If your Delta Inverter displays 'AC Volt Low' (E10, E15, E20), the issue might stem from a few potential causes. Initially, verify that the actual utility voltage is within the suitable range, as it may be under the UVR setting. Also, incorrect Grid code or Grid settings could be the cause, so check them. Another potential cause is wrong connections in the AC terminal, so check the AC terminal connections. If these steps don't resolve the issue, there might be a detection circuit malfunction, in which case you should contact customer service for technical support.
  • M
    Mrs. Christy JohnsonAug 25, 2025
    Why does my Delta M42U Inverter show 'No Grid (E09)' error?
    • W
      William HooverAug 26, 2025
      If your Delta Inverter is showing a 'No Grid (E09)' error, the possible causes are: 1. The AC breaker is OFF. In this case switch on the AC breaker. 2. There is a disconnection in the AC terminal. In this case check the connection in the AC terminal and ensure it connects to the inverter.
  • H
    Heather KellySep 23, 2025
    What does DC Cur. High (F60, F61, F70, F71) error mean on my Delta M42U?
    • R
      Rhonda LewisSep 23, 2025
      If your Delta Inverter is showing a 'DC Cur. High (F60, F61, F70, F71)' error, the possible causes are: 1. Switching device in boost is defective, so check all switching device in boost. 2. Driver for boost is defective, so check the driver circuit for boost inside the inverter. 3. Input current detection circuit malfunction, so check input current detection circuit.
  • R
    Rebecca MorrisonSep 13, 2025
    What does HW Red ADC2 (F19) error mean on my Delta M42U?
    • D
      danielcassieSep 13, 2025
      If your Delta Inverter displays 'HW Red ADC2 (F19)', potential causes include: 1. Insufficient input power, so check the input voltage, which must be >150Vdc. 2. Auxiliary power circuitry malfunction, so check the auxiliary circuitry inside the inverter. 3. A detection circuit malfunction, and you should contact customer service for technical support.
  • D
    Dale ButlerSep 18, 2025
    What does Bus Unbal. (F30) error mean on my Delta Inverter?
    • D
      David GonzalesSep 19, 2025
      If your Delta Inverter displays 'Bus Unbal. (F30)', it may be caused by: 1. Not totally independent or parallel between inputs, so check the inputs connections. 2. PV Array short to Ground, so check the PV Array insulation. 3. Driver for boost is defective or disconnected, so contact customer service for technical support.
  • R
    Rebecca JuarezSep 6, 2025
    What should I do if my Delta Inverter shows HW NTC2 Fail (F08)?
    • T
      Tiffany BellSep 6, 2025
      If your Delta Inverter displays 'HW NTC2 Fail (F08)', it could be due to: 1. Ambient temperature >90 ? or
  • L
    Lindsey CareySep 7, 2025
    What causes HW NTC3 Fail (F09) error on my Delta Inverter?
    • K
      kristinortizSep 7, 2025
      If your Delta Inverter displays 'HW NTC3 Fail (F09)', the problem might be: 1. Ambient temperature >90 ? or
  • K
    Kelly RiveraSep 23, 2025
    What does HW AC OCR (F45) error mean on my Delta M42U?
    • M
      Michele FordSep 23, 2025
      If your Delta Inverter displays 'HW AC OCR (F45)', it could be due to: 1. Large Grid harmonics, so check the utility waveform. Grid connection of inverter needs to be far away from non-linear load if necessary. 2. Switching device is defective, so check all switching devices in inverter stage. 3. A detection circuit malfunction, so contact our customer service for technical support.
  • G
    George MoralesAug 30, 2025
    How to troubleshoot Solar1 High (E30) error on Delta M42U?
    • T
      Theresa MartinAug 30, 2025
      If your Delta Inverter shows 'Solar1 High (E30)', it might be caused by: 1. MPPT 1 input voltage being over 1000Vdc, so modify the solar array setting to make the Voc less than 1000Vdc. 2. A detection circuit malfunction, and you should contact customer service for technical support.

Delta M42U Specifications

General IconGeneral
Max. DC Voltage1100 V
AC Voltage400 V
Efficiency98.6%
Output Voltage400 V
Frequency50/60 Hz
Communication InterfaceEthernet, RS485
MPPT Voltage Range200-1000 V
Input Voltage200-1000 V