a) Output Current Rating (A)
b) Minimum normal ramp-up rate (%Irated /sec)
c) Maximum normal ramp-up rate (%Irated /sec)
d) Minimum output current
e) Ramp Rate Accuracy MSARR(%Irated /sec)
43.3A
1.11%/sec
0.4%/sec
0.1A
2%/sec
Irated
RRnorm_up_min
RRnorm_up_max
Ilow
-
50.5A 33.7A
Appendix A-3: CA R21 Settings – Normal Ramp Rate (RR)
& Soft-Start Ramp Rate (SS)
M36UM42UAlias M28U
Appendix A-4: CA R21 Settings – Soft-start ramp rate test
a) Output Current Rating (A)
b) Minimum soft start ramp-up rate (%Irated /sec)
c) Maximum soft start ramp-up rate (%Irated /sec)
d) Ramp Rate Accuracy MSARR(%Irated /sec)
43.3A
0.167%/sec
3.33%/sec
2%/sec
M28U
33.7A
M36UM42U
50.5A
Irated
RRss_min
RRss_max
-
Alias
Appendix A-5: CA R21 Settings – Specified Power Factor
a) Apparent Power Rating (VA)
b) Output Power Rating (W)
c) DC Input voltage range with function enabled (V)
d) Nominal AC voltage (V)
e) AC voltage range with function enabled (V)
f) AC voltage measurement accuracy (V)
g) DC voltage measurement accuracy (V)
h) Active power range of function, e.g., 20-100% of nameplate
i) Power Factor Accuracy
j) Power Factor Settling Time
k) Minimum Inductive (Underexcited) Power Factor
l) Minimum Capacitive (Overexcited) Power Factor
m) PF, the inductive or capacitive signed power factor
commanded for test
n) PFmid,cap = (1 + PFmin,cap)/2, middle of the EUT
capacitive range.
o) PFmid,ind = (1 + PFmin,ind)/2, middle of the EUT
inductive range.
p) POutlimit, the maximum output power either limited by the
input supply or by a command to the inverter.
q) PFtarget, the target power factor. This will differ from the
commanded power factor in ‘Active Power Priority’ modes
for input power greater than PX
Srated
Prated
Vdc_range
Vnom
Vac_range
MSAVac
MSAVdc
[Plow, Prated]
MSAPF
(s)
PFmin,ind
PFmin,cap
PFdesird
PFmid,cap
PFmid,ind
POutlimit
PFtarget
Alias
M42U
46000VA
42000W
[9200W,
46000W]
46000W
[200V, 1000V]
277V
[249.3V, 304.7V]
± 2.77V
± 10V
± 0.01
10s
0.8
0.8
[0.8cap, 0.8ind]
0.9
0.9
[0.8cap, 0.8ind]
M36U
39600VA
36000W
[7920W,
39600W]
39600W
M28U
30800VA
28000W
[6160W,
30800W]
30800W
Appendix A: Rule 21