EasyManua.ls Logo

Delta M60U - User Manual

Delta M60U
130 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
M80U
M60U
Operation and Installation Manual
Grid-tie Transformerless Solar Inverter
The power behind competitiveness
www.deltaww.com

Table of Contents

Questions and Answers

  • M
    meyerangelaAug 28, 2025
    How to troubleshoot Solar1 High (E30) error on Delta Inverter?
    • A
      anthonyrobertsonAug 28, 2025
      If your Delta Inverter shows 'Solar1 High (E30)', it might be caused by: 1. MPPT 1 input voltage being over 1000Vdc, so modify the solar array setting to make the Voc less than 1000Vdc. 2. A detection circuit malfunction, and you should contact customer service for technical support.
  • H
    hwilsonSep 18, 2025
    What causes HW RLY (F13) error on Delta M60U?
    • R
      Randy WeberSep 18, 2025
      The HW RLY (F13) error on your Delta Inverter can be caused by a defective driver circuit for the relay, a defective relay(s), or a detection circuit malfunction (Inverter voltage). Check the input voltage, it must be >150Vdc. Replace the defective relay.
  • E
    Elizabeth JonesAug 28, 2025
    What does AC Surge DC Surge error mean on my Delta Inverter?
    • F
      Francisco GreerAug 29, 2025
      If your Delta Inverter displays 'AC Surge DC Surge', possible causes include: 1. The inverter was struck by lightning, so check the inverter’s status. 2. One or more SPD are defective, so replace the defective SPD. 3. One or more SPD are disconnected, so check the connections of SPDs. 4. A detection circuit malfunction, so check the connection in AC terminal. 5. Wrong connection in AC terminal, so contact customer service for technical support.
  • S
    sanchezamyAug 29, 2025
    Why is my Delta M60U Inverter showing a Temperature (F07) error?
    • D
      Darin WebsterAug 29, 2025
      If the Delta Inverter displays 'Temperature (F07)', it could be due to: 1. Ambient air is less than -30?, so check the installation ambient and environment. 2. A detection circuit malfunction, and you should contact customer service for technical support.
  • I
    iclarkAug 29, 2025
    What does Solar1 Low (W01) error mean on my Delta M60U Inverter?
    • L
      Lisa TaylorAug 29, 2025
      If your Delta Inverter is showing a 'Solar1 Low (W01)' error, it might be because: 1. MPPT 1 input voltage is under the limit, so check the MPPT 1 voltage connection to the inverter terminal. 2. Some devices were damaged inside the inverter if the actual MPPT 1 voltage is close to "0", so check all switching devices in boost1. 3. There is a detection circuit malfunction, and you should contact customer service for technical support.
  • K
    Kristen SingletonSep 23, 2025
    What causes Ground Cur. (F24) error on Delta Inverter?
    • A
      Angela BeckerSep 23, 2025
      The Ground Cur. (F24) error on your Delta Inverter can be caused by a PV array insulation fault, large PV array capacitance between Plus to Ground or Minus to Ground, malfunction of either side of boost driver or boost choke, or a detection circuit malfunction. Check the insulation of Solar inputs. Check the capacitance (+ GND & - GND), must < 2.5uF. Install external transformer if necessary
  • M
    Mitchell CookSep 15, 2025
    What does Temperature (F07) error mean on Delta Inverter?
    • C
      Catherine FrancisSep 15, 2025
      If your Delta Inverter shows a Temperature (F07) error, it means that the ambient air is less than -30? or there is a detection circuit malfunction. Check the installation ambient and environment.
  • M
    Maria DavisSep 12, 2025
    What causes AC Freq Low (E02) error on Delta Inverter?
    • J
      John NealSep 12, 2025
      The AC Freq Low (E02) error on your Delta Inverter can occur if the actual utility frequency is under the UFR setting, the Grid code or Grid setting is incorrect, or there's a detection circuit malfunction. Check the utility frequency and verify the Grid code and Grid setting.
  • M
    Michael CunninghamAug 31, 2025
    What should I do if my Delta M60U Inverter shows HW NTC2 Fail (F08)?
    • M
      Mr. Oscar RoseAug 31, 2025
      If your Delta Inverter displays 'HW NTC2 Fail (F08)', it could be due to: 1. Ambient temperature >90 ? or
  • M
    Michael VelasquezAug 31, 2025
    What causes HW NTC3 Fail (F09) error on my Delta M60U Inverter?
    • J
      Jason PerezSep 1, 2025
      If your Delta Inverter displays 'HW NTC3 Fail (F09)', the problem might be: 1. Ambient temperature >90 ? or

Summary

Safety

Information of the Inverter

Provides legal provisions and identifies the target audience for the manual.

General Safety

Covers essential safety practices, warnings, and symbols for safe operation.

Introduction

Valid Model

Lists the supported inverter model numbers for which this manual is applicable.

Product Overview

Details the inverter's components, models, and general features with diagrams.

Installation

Mechanical Installation

Guides on physical mounting of the inverter, including wall and tilt options.

Electrical Installation for AC Wiring

Covers AC wiring procedures, connections, and required devices for grid connection.

Electrical Installation for DC Wiring

Covers DC wiring procedures, connections, and grounding for PV array inputs.

Communication Module Connections

Explains how to connect communication modules and RS-485 interfaces.

Commissioning

First startup

Outlines the initial setup routine for language, grid code, and ID settings.

Main Menu Functions

Introduces the inverter's operational menu, including monitoring and settings.

Install Settings

Accesses critical configuration parameters like Inverter ID, Grid Code, and Grid Settings.

Maintenance

Removing and re-installing the Wiring Box (WB) cover

Provides procedures for accessing the inverter's internal components.

Component Replacement

Procedures for replacing SPD, fuses, and fans, ensuring system integrity.

De-Commissioning

Outlines the safe procedure for removing the inverter from operation.

Error message and Trouble Shooting

Error, Warning, and Fault Codes

Lists common error messages, their causes, and troubleshooting actions.

Calling for Help

Provides information required for contacting technical support efficiently.

Technical Information

M80 U Series Specifications

Lists detailed technical specifications for the M80U inverter models.

M60 U Series Specifications

Lists detailed technical specifications for the M60U inverter models.

APPENDIX: Grid Support Utility Interactive Inverters

Appendix A: Rule 21

Details CA Rule 21 settings for voltage and frequency ride-through.

Appendix B: HECO

Provides HECO specific settings for ride-through capabilities.

Appendix C: Assembly Note

Offers assembly guidance and screw torque specifications for various models.

Delta M60U Specifications

General IconGeneral
AC Voltage [V]400
Output Power60 kVA
Frequency50 / 60 Hz
CategoryInverter
Output Voltage400 V
Protection FeaturesOvervoltage protection

Related product manuals