Chapter 7 Optional AccessoriesMS300
116
LED
Descriptions
CANopen–ERR
ERR LED:
LED
status
Condition/ State
OFF
No Error
Single
Flash
At least one packet of CANopen is in failure
Double
Flash
Node guarding failure or heartbeat message failure
Triple
Flash
Synchronization failure
ON
Bus off