Chapter 12 Description of Parameter SettingsMS300
457
12-2 Adjustment & Application
The followings are abbreviations for different types of motors:
IM: Induction motor
PM: Permanent magnet synchronous AC motor
IPM: Interior permanent magnet synchronous AC motor
SPM: Surface permanent magnet synchronous AC motor
12-2-1 Permanent-Magnet Synchronous Motor, Space Vector Control Adjustment Procedure
(PM SVC, Pr.00-11 = 2)
PMSVC Control diagram
AVR
Acc/Dec Time
VSR
VSR
Current
Detection
IGBT
PWM
PM
Pr.07-23
Pr.01-01~01-02
Pr.05-33~05-43
+
Pr.07-38
Pr.01-12~01-27
Fcmd
Pr.00-20
+
U
a
U
b
U
c
LPF
LPF
Torque
Compensation
Pr.07-24
Pr.07-26
Pr.10-31
U
a
U
b
U
c
LPF
Frequency
Compensation
Pr.10-34
Pr.10-32
I
a
I
b
I
c
DC Bus
Voltage
Detection
DC Bus
Voltage
Protection
++

Table of Contents