EasyManuals Logo

Delta MS300 Series User Manual

Delta MS300 Series
805 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #781 background imageLoading...
Page #781 background image
Chapter 17 Safe Torque Off FunctionMS300
772
17-5 Reset the Parameter Settings
Use Pr.06-44 to specify the reset method when an STO alarm occurs.
06-44
STO Latch Selection
Default: 0
Settings
0: STO Latch
1: STO No latch
Pr.06-44 = 0: STO Alarm Latch. After you clear the cause of the STO Alarm, use a Reset
command to clear the STO Alarm.
Pr.06-44 = 1: STO Alarm no Latch. After you clear the cause of the STO Alarm, the STO Alarm
clears automatically.
All of STL1–STL3 errors are “Alarm Latchmode (in STL1–STL3 mode, the Pr.06-44 function is
not available).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta MS300 Series and is the answer not in the manual?

Delta MS300 Series Specifications

General IconGeneral
BrandDelta
ModelMS300 Series
CategoryStorage
LanguageEnglish

Related product manuals