EasyManuals Logo

Delta MS300 Series User Manual

Delta MS300 Series
805 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #300 background imageLoading...
Page #300 background image
Chapter 12 Descriptions of Parameter SettingsMS300
291
01-34
Zero-speed Mode
Default: 0
Settings
0: Output waiting
1: Zero-speed operation
2: Fmin (refer to Pr.01-07, Pr.01-41)
When the drive’s Frequency command is lower than Fmin (Pr.01-07 and Pr.01-41), the drive
operates according to this parameter.
0: the AC motor drive is in waiting mode without voltage output from terminals U, V, W.
1: the drive executes the DC brake by Vmin (Pr.01-08 and Pr.01-42) in V/F, FOC sensorless, and
SVC modes. And it executes zero-speed operation in VFPG mode.
2: the AC motor drive runs using Fmin (Pr.01-07 and Pr.01-41) and Vmin (Pr.01-08 and Pr.01-42)
in V/F, VFPG, SVC and FOC sensorless modes.
In V/F, VFPG, SVC and FOC sensorless modes:
Pr.01-11 lower limit > Pr.01-07 Fmin
Pr.01-11 lower limit < Pr.01-07 Fmin

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta MS300 Series and is the answer not in the manual?

Delta MS300 Series Specifications

General IconGeneral
BrandDelta
ModelMS300 Series
CategoryStorage
LanguageEnglish

Related product manuals