Chapter 14 Fault CodesMS300
625
ID
Display on LCD Keypad
Fault Name
Fault Descriptions
140
oc hardware error
(Hd6)
GFF hardware protection error when power is ON.
Action and Reset
Action Condition
Hardware detection
Action Time
Immediately act when the fault is detected
Fault Treatment Parameter
N/A
Reset Method
Power-off
Reset Condition
N/A
Record
Yes
Cause
Corrective Actions
Hardware failure
Cycle the power.
If Hd6 still exists, return to the factory for repair.