EasyManua.ls Logo

Delta TP70P-211LC1T - Page 79

Delta TP70P-211LC1T
86 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5 Devices
5-23
5__
_
Special
D
Item Description Attibutes Default
K7: 200 ms
K8: 400 ms
D4532 Subtract tare
K0: disable
K1: subtract tare
K2: not subtract tare
K3: reset to zero
Once the setting is done, the status switches
back to ON. (M1667 = ON
R/W
K0
D4533 Gross / net weight seleciton K0: gross weight ; K1: net weight R/W
K0
D4534 Times to check the stability K1 ~ K500 R/W
K5
D4535
Times to check the stabilitiy
range
K1 ~ K10000 R/W
K10
D4536 Upper limit of the zero return K0 ~ K32767 R/W
K10
D4537 Lower limit of the zero return K-1 ~ K-32768 R/W
K-10
D4538 Excitation voltage setting Unit 0.1 V; setting range: K20 ~ K100 R/W
K50
D4539 Maximum weight (Low word)
You can set the maximum value and when the
measured weight exceeding the maximum
value, an error code will be recorded.
R/W
K100000
D4540
Maximum weight (High
word)
R/W
D4541 Filter mode setting
K0: no filter
K1: filter out the measured maximum weight
K2: average weights
R/W
K0
D4542
Mode of filtering out the
measured maximum weight
K0 ~ K8
The greater the setting value is, the greater the
filtering is
R/W
K0
D4543 Mode of averaging weights K1 ~ K100 R/W
K1
D4544
Setting how many digits can
be set on the left of the
decimal point
K0 ~ K4 R/W
K0
D4549 Zero point tracking range
Setting range: K0 ~ K30000; when set the
setting to 0, it indicates zero point tracking is
disabled.
R/W
K0
D4550 Zero point tracking time Setting range: K5 ~ K1000; unit: 0.1 s R/W
K5
D4551
Weight value before
resetting to zero (Low word)
Display the weight value before resetting to
zero
R
K0
D4552
Weight value before
resetting to zero (High word)
R
K0
D4553
Display tare weight
(Low word)
Display tare weight
Work with D4532=1 to edit the tare weight
When D4532=2, the tare weight cannot be edit.
R/W X K0
D4554
Display tare weight
(High word)
R/W X K0
D4555
Display the time of the
weight measured
Setting range: K0 ~ K10000; unit: 1 ms;
K0: present weight
R/W
K1000

Related product manuals