TP70P-211LC1T/TP04P-20EXL1T Operation Manual
5-24
_5
Special
D
Item Description Attibutes Default
D4562 Digital input modes X20
Mode setting:
H’0: digital input point (default)
H’1: ON; a weight is restoreto zero
H’2: ON; a tare is measured
H’3: ON; a tare is subtracted
H’4: OFF; a net weight is measured;
ON; a gross weight is measured
H’6: ON; zero point is calibrated
H’7: ON; the 1
st
point is calibrated
H’8: rising edge triggered;
open outputs Y20 ~ Y27
falling edge triggered:
close outputs Y20 ~ Y27
H’9: rising edge triggered;
close outputs Y20 ~ Y27
falling edge triggered:
open outputs Y20 ~ Y27
H’A: rising edge triggered;
hold outputs Y20 ~ Y27
falling edge triggered:
open outputs Y20 ~ Y27
H’B: rising edge triggered;
open outputs Y20 ~ Y27
falling edge triggered:
hold outputs Y20 ~ Y27
R/W
H’0
H’A and H’B:
When the status is Hold, the status of
Y20-Y27 cannot be changed; D566 = 2
(HOLD)
When the status is Open, output the status
of the modified Y20-Y27.
R/W
H’0
D4563
Digital output modes
Y20 ~ Y23
b15-b12
b11-b8
b7-b4
b3-b0
Y23 Y22 Y21 Y20
H’0: digital output point (default)
H’1: ON, when there is no load on the load cell
H’2: OFF, when there is no load on the load cell
H’3: ON, when the weight is larger than the
specified maximum weight
H’4: OFF, when the weight is larger than the
specified maximum weight
H’5: ON, when the excitation voltage is
abnormal
H’6: OFFm when the excitation voltage is
abnormal F
H’7: ON, when the weight is in the specified
stability range
H’8: OFF, when the weight is in the specified
stability range
H’9: ON, when the weight is greater than the
R/W
H’0