Chapter 11 Summary of Parameter Settings | VFD-ED
Pr. Parameter Name Setting Range Default
VF
direction detection when in normal
mode.
06-47
Power Generation
0.0–5.0 sec. 1.0 ○ ○ ○ ○ ○
06-48
Power Capacity of
Emergency Power (EPS)
0.0–100.0 kVA 0.0 ○ ○ ○ ○ ○
06-49
STO Latch Selection
0000h: STO fault latched, resending
RUN command is required
0001h: STO warning latched, resending
RUN command is required
0002h: STO fault latched
0003h: STO warning unlatched
0000h ○ ○ ○ ○ ○
06-50
MO’s Action when
Retrying after Fault
0 ○ ○ ○ ○ ○
06-51
Number of Times to Retry
after Fault
0–10 0 ○ ○ ○ ○ ○
06-52
Time Interval between
Retries
0.5–600.0 sec. 10.0 ○ ○ ○ ○ ○
06-53
Frequency Command
when the Most Recent
0.00–655.35 Hz
Read
only
○ ○ ○ ○ ○
06-54
the Most Recent Fault
0.00–655.35 Hz
Read
only
○ ○ ○ ○ ○
06-55
Output Current when the
Most Recent Fault
0.00–655.35 Amps
Read
only
○ ○ ○ ○ ○
06-56
the Most Recent Fault
0.00–655.35 Hz
Read
only
○ ○ ○ ○ ○
06-57
Output Voltage when the
Most Recent Fault
0.0–6553.5 V
Read
only
○ ○ ○ ○ ○
06-58
the Most Recent Fault
0.0–6553.5 V
Read
only
○ ○ ○ ○ ○
06-59
Output Power when the
Most Recent Fault
0.0–6553.5 kW
Read
only
○ ○ ○ ○ ○
06-60
Most Recent Fault
0.00–655.35%
Read
only
○ ○ ○ ○ ○
06-61
IGBT Temperature when
the Most Recent Fault
-3276.8–3276.7ºC
Read
only
○ ○ ○ ○ ○