Chapter 4 Description of Parameters | VFD-VJ
4-34

Minimum Flow 2
Control mode
VF FOCPG FOCPM
Factory setting: 5.00
Settings 0.00 ~ 100.00%
The setting value at Pr.01-02 Maximum Operating Frequency is the 100% of this parameter Pr.00-62.

Pressure Releasing Valve Opening Time Interval
Control mode
VF FOCPG FOCPM
Factory setting: 0.100
Settings 0.000 ~ 0.100 sec
The output signal MO-46 opens the pressure releasing valve when:
1) Speed command is to run reversely,
2) Pressure command is to decrease the pressure
3) The elapsed time is longer than time set at Pr.00-63.
4) The feedback pressure doesn’t reach yet the stable pressure zone.
Use Pr.00-63 to set up the time interval between opening and closing pressure releasing valve to avoid
unnecessary valve opening and closing (ON / OFF)
~
For specific customers only
Multi-flow rate / speed command 1
Control mode
VF FOCPG FOCPM
Factory setting: 0
Settings 0.00 ~ 599.00Hz
Multi-flow rate / speed command 2
Control mode
VF FOCPG FOCPM
Factory setting: 0
Settings 0.00 ~ 599.00Hz
Multi-flow rate / speed command 3
Control mode
VF FOCPG FOCPM
Factory setting: 0
Settings 0.00 ~ 599.00Hz
Multi-flow rate / speed command 4
Control mode
VF FOCPG FOCPM
Factory setting: 0
Settings 0.00 ~ 599.00Hz