Chapter 3. Machine Adjustment Procedure | VFD-VJ 
 
3-22
3-5 Confluence/Diversion Mode Adjustment Procedure 
Wiring according to Chapter 2 
In a diversion condition, adjust various parameters of the hybrid servo drive according to the   
Step 1 – Step 8 describe above 
In a confluence condition, please refer to the machine adjustment procedure for the confluence 
operation 
Complete the above steps 
Set the Master for pressure control mode 
  Pr.00-09 = 1 for pressure control mode 
Pressure control mode 
Setting value   
of Pr.00-09 
0: Speed control 
1: Pressure control   
Set the Slave for speed control mode 
  Pr.00-09 = 0 for speed control mode 
Speed Control Mode 
Setting value   
of Pr.00-09 
0: Speed control 
1: Pressure control   
 
  Pr.03-00 ~ Pr.03-02 = 45 confluence/diversion signal input 
Multi-function Input 
Setting values   
of Pr.03-00~03-02 
0: No function 
45: Confluence/Diversion signal input   
  Through the controller, perform the entire confluence/diversion operation. 
  New protection mechanism at version C: When Pr.03-00 ~ Pr.03-02 = 45, Pr.01-01 is 
automatically set as 2 and Pr.03-15 is automatically, set as 1. This is a mechanism to prevent 
forgetting to set up related parameters and mistakes when setting up parameters.