Chapter 4 Description of Parameters | VFD-VJ
4-51
Output of DC side voltage at malfunction
Control mode
VF FOCPG FOCPM
Factory setting: Read only
Settings 0.0 – 6553.5V
Output current at malfunction
Control mode
VF FOCPG FOCPM
Factory setting: Read only
Settings 0.00~655.35Amp
IGBT temperature at malfunction
Control mode
VF FOCPG FOCPM
Factory setting: Read only
Settings
-3276.7~3276.7℃
Auto-reset LvX error
Control mode
VF FOCPG FOCPM
Factory setting: 0
Settings 0: Disable, 1: Enable
When this parameter is enabled and when there is RUN signal, the hybrid servo drive will
automatically restart after repowering on.
~ Reserved
Frequency command at malfunction
Control mode
VF FOCPG FOCPM
Factory setting: Read only
Settings 0.00 – 599.00Hz
Capacitors’ temperature at malfunction
Control mode
VF FOCPG FOCPM
Factory setting: Read only
Settings
-3276.7~3276.7℃
Motor’s rotating speed at malfunction
Control mode
VF FOCPG FOCPM
Factory setting: Read only
Settings -32767~32767rpm
Torque command at malfunction
Control mode
VF FOCPG FOCPM
Factory setting: Read only
Settings
-32767~32767%
Input terminals status at malfunction
Control mode
VF FOCPG FOCPM
Factory setting: Read only
Settings 0~65535
Output terminals status at malfunction
Control mode
VF FOCPG FOCPM
Factory setting: Read only
Settings 0~65535
Hybrid servo drive status at malfunction
Control mode
VF FOCPG FOCPM
Factory setting: Read only
Settings 0~65535