Chapter 4 Description of Parameters | VFD-VJ 
 
4-3
 
Pr.    Name of Parameter  Setting 
Factory 
Setting 
VF 
FOCPG 
FOCPM 
 
00-04 
Selection of 
multi-function  
display 
0: Display the output current (A) 
1: Reserved 
2: Display the actual output frequency (H) 
3: Display the DC bus voltage (U) 
4: Display the output voltage (E) 
5: Display the output power angle (n) 
6: Display the output power in kW (P) 
7: Display the actual motor speed rpm (r) 
8: Display the estimated output torque N-m 
(t) (%) 
9: Display the PG feedback (G) 
10: Reserved 
11: Display the signal value of the analog 
input terminal PO % (1.) 
12: Display the signal value of the analog 
input terminal PI % (2.) 
13: Display the signal value of the analog 
input terminal AUI % (3.) 
14: Display temperature of the heat sink in 
°C (t.) 
15: Display temperature of IGBT in °C (T) 
16: The status of digital input (ON/OFF) (i) 
17: The status of digital output (ON/OFF) (o) 
18: Reserved 
19: The corresponding CPU pin status of the 
digital input (i.) 
20: The corresponding CPU pin status of the 
digital output (o.) 
21~24: Reserved 
25: Display the signal value of the analog 
input terminal QI % (5.) 
26: Display the actual pressure value (Bar) 
(b.) 
27: Display the kWh value (K) 
28: Display the motor temperature (currently 
only support KTY84) (T.) 
29: Overload rate of hybrid servo drive (d.) 
(unit: %) 
30: Over load rate of motor with last digit A of 
HES. (M.) (unit: %) 
31: Display current at braking (A.) (unit: A) 
32: Temperature of the braking chopper (4.) 
(unit: ºC)   
33: Reserved 
34: Torque constant Kt (K.)   
35: Reserved 
36: Reserved 
37: Reserved 
38: Reserved 
39: Reseerved 
40: Reserved 
41: # of times to switch on/off of the soft start 
relays (L) (%) 
42: Amount of time to clean the cooling fans 
(F) % 
0  ○  ○  ○ 
 
00-05 Reserved    0       
 
00-06 
Display the speed (rpm)   
defined by the user 
0~39999 rpm 
2000 
○  ○  ○