Symptom Probable Cause Suggested Remedy
Hot water
does not
enter tub in
wash
Water Valve Coil Check coil continuity at terminals and replace if no continuity.
Check for 120 VAC power (60 Hz) from main relay PCB. (24 VAC
for 50 Hz models)
Water Inlet Check water inlet screens for blockage and clean if necessary
screens
Water Check to insure that water is turned on and operating.
Check Voltage If appropriate voltage is not present at the valve, refer to the wiring
diagram for your specic washer model. Check for voltage at the
P4 Connector on the Relay PCB. Check for LED indication that
the appropriate relay is activated.
Pressure Switch Check pressure switch continuity between terminals . If no con-
tinuity, check pressure switch hose for obstruction. If hose okay,
change pressure switch.
No cold wa-
ter to tub in
wash
Water Valve Coil Check coil continuity at terminals and replace if no continuity.
Water Inlet Screens Check water inlet screens for blockage and clean if necessary.
Water Check to insure that water is turned on and operating.
Check Voltage If appropriate voltage is not present at the valve, refer to the wiring
diagram for your specic washer model. Check for voltage at the
P4 Connector on the Relay PCB. Check for LED indication that
the appropriate relay is activated.
Pressure Switch Check pressure switch continuity between terminal contacts. If
no continuity, check pressure switch hose for obstruction. If hose
okay, change pressure switch.
Water comes
in but level
does not rise
Drain Valve (open) Check these areas:
• Drain valve blockage
• Drain valve motor and gear train. If power but drain valve does
not close, replace valve.
• Power to the drain valve. If no power to drain valve, check circuit
for power.
Check Voltage If appropriate voltage is not present at the valve, refer to the wiring
diagram for your specic washer model. Check for voltage at the
P4 Connector on the Relay PCB. Check for LED indication that
the appropriate relay is activated.
Water does
not ush soft-
ener com-
partment.
Water Valve Coil Check coil continuity at terminals and replace if no continuity.
Water Inlet Screens Check water inlet screens for blockage and clean if necessary.
Water Check to insure that water is turned on and operating.
Water does
not ush
softener
compart-
ment.
Pressure Switch Check pressure switch continuity between terminals. If no
continuity, check pressure switch hose for obstruction. If
hose okay, change pressure switch.
Water level
too high
Pressure Switch Check for blockage in pressure switch hose. Check for
pressure switch opening circuit across terminals . Replace
switch if contacts do not open.
Water
drains
slowly
Drain System Check hoses and drain valve for blockage. Clean of inade-
quate size. If necessary. Check building drains for blockage
45