MODEL BMG-535 GRINDER
SECTION 9 FAULT DIAGNOSIS
65
OPERATING MANUAL
APRIL 2009
Grinding & Polishing
Fault Possible Cause Remedy
Motor does not
switch on
Under voltage trip due to
power interruption
Defective Component
GFCI device
tripped
Check the main power
supply for proper voltage
and switch on again.
Troubleshoot and
replace defective
component.
Reset GFCI device and
retry. If device trips
again, determine cause
and replace.
Motor turns off
while running
Motor protection switch
triggered because of
overload.
Motor protector switch tripped
because of low or under
voltage condition.
Motor defective.
Reduce additional load
or increase extension
cord wire size.
Increase extension cord
wire size.
Have motor checked by
a trained professional to
confirm.
9.2 TROUBLESHOOTING – ELECTRICAL SYSTEM
Work on electrical equipment or operating materials may only be
performed by a skilled electrician or by trained persons under the
guidance and supervision of a skilled electrician as well as in
accordance with the electrical en
g
ineerin
g
re
g
ulations.
Prior to any repair work on the machine or its drives, the
machine must be secured against unintentional activation. Put
the machine in its Safety off position. See section 26.