Horizontal-Schrumpfgerät
Horizontal Shrinking Device
HS 1100-P
BA_79-329_0_D+E.docx
Copyright © Diebold 2017-04 Ersteller: kh
Seite 42 von 60
19.3. LCD-Messages
After switching on the device the
Software version (in picture "v02.1")
and the
Number of shrink cycles (in picture "82")
will be displayed for approx. 3 seconds.
The following messages may appear in the LC display:
ATTENTION! Heating time too long !!
the maximum permissible heating time has been exceeded. Heating of the shrink
chuck will automatically be stopped
• Max. temp. coil, please wait -
the maximum permissible coil temperature has been exceeded. Please wait a few
minutes until the inductor has cooled down
• Max. temp. IGBT, please wait -
the maximum permissible IGBT temperature (transistors in the generator) has
been exceeded. Please wait a few minutes until the IGBTs have cooled down
Fault !! -
a fault has occurred
Overload -
the generator is overloaded
IGBT Error -
an IGBT error has occurred
If error messages continue even after switching the unit off and back on, please contact
the manufacturer.
(Observe the cool down of the generator!)