8.1 Installation Notes
The IOX unit must be earthed to the mains earth (ground) and installed according to the safety instructions included with the unit.
The unit is powered from an IEC inlet on the rear. This must be connected to an earthed mains outlet using a cable that complies
with local approvals and regulations.
Approvals cover use in ambient air temperature of up to 35°C. Operation in higher temperatures should be avoided. A 1U space
should be left above and below the unit to prevent heat transfer from adjacent equipment, if this generates heat above 35°C.
At least 75 mm (3 inches) should be allowed to the sides of the unit to allow ventilation. At least 75 mm (3 inches) of free air should
be left at both the front and the rear side of the rack to allow heat dissipation. Under no circumstances should the fan (where tted)
or ventilation outlets be blocked or restricted.