Calibrating the Expression Pedal
If the Expression Pedal’s range becomes diminished over time, it may be
necessary to re-calibrate the pedal. Here is the procedure for calibration:
1. Begin with the power disconnected from the Expression Factory
TM
.
2. Select Model 1 using the MODEL knob.
3. Insert a standard mono (TS) guitar cable into the FOOTSWITCH
jack.
4. Connect the power supply to the Expression Factory. The INDICA-
TOR LED begins flashing green.
5. Rock the EXPRESSION PEDAL forward (toe down).
6. Select Model 2 using the MODEL knob. The INDICATOR LED
begins flashing yellow.
7. Rock the EXPRESSION PEDAL back (toe up).
8. Select Model 3 using the MODEL knob. The INDICATOR LED
should flash green three times if calibration was successful.
If the calibration procedure fails, the INDICATOR LED will flash red
instead of green during step 8 and the unit will not return to normal
operation until the Expression Pedal has been properly calibrated. Select
Model 1 using the MODEL knob at this time and repeat steps 5-8 until
Expression Pedal calibration is successful.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DigiTech Expression EX-7 Factory and is the answer not in the manual?

DigiTech Expression EX-7 Factory Specifications

General IconGeneral
BrandDigiTech
ModelExpression EX-7 Factory
CategoryMusic Pedal
LanguageEnglish

Related product manuals