To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
Fireplace Installation
screws down on replace
chassis.
11. Screw the two supplied #8
square head screws through
two of the permanent mount-
ing holes which align with a
wall stud.
12. Carefully replace and install
partially reflective glass and
glass brackets using screws
from step 1.
13. Refer to Front Glass Installa-
tion section for nal installation
procedures.
In-wall Recessed Installation
- 2x4 Framing
CAUTION: Two people may
be required for various steps
of this procedure.
1. Prepare a wall with a framed
opening of 46 ½ in. (118.1 cm)
wide x 16 ½ in. (42 cm) high
(Figure 9).
!
NOTE: The sizing has allowed
for 1/4 in. (6.4 mm) around the
replace insert for ease of instal-
lation. This replace does not
require any additional venting.
2. Choose your method of sup-
plying power to the unit:
Plug in (you may run the pow-
er cord out of the framed wall
opening to an existing outlet
or install an outlet on a nearby
wall stud within the wall).
Hard wire the replace (rec-
ommended). Follow the hard
wiring instructions on page 8.
WARNING: Do not attempt
to wire your own new outlets or
circuits. To reduce the risk of re,
electric shock or injury to persons,
always use a licensed electrician.
WARNING: Ensure that the
circuit on which the replace is to
be installed has the power cut off
at the service panel until installa-
tion is complete.
3. Lift replace and insert into
opening (Figure 10).