11
Fireplace Installation
and anchor in place using
glass brackets and screws
removed in step 1.
16. Refer to Front Glass Installa-
tion section, for nal installa-
tion procedures.
For Bathroom Use
If this unit is installed in a bath-
room it must be protected by a
GFI receptacle or circuit. If recep-
tacle is used it must be readily
accessible.
This electrical applicance is not
watertight. To prevent electrical
shock, it must be installed as to
prevent water from entering unit.
This must be installed away from
showers, tubs, etc. Never locate
replace where it may fall into a
bathtub or other water container.
Surface Installation
CAUTION: Two people may
be required for various steps
of this procedure.
1. Choose a location which has
a minimum of two wall studs
available for mounting.
2. Choose your method of sup-
plying power to the unit:
• Plug in to an existing outlet or
install an outlet nearby.
• Hard wire the replace. Follow
the hard wiring instructions on
page 8.
WARNING: Do not attempt
to wire your own new outlets or
circuits. To reduce the risk of re,
electric shock or injury to persons,
always use a licensed electrician.
WARNING: Ensure that the
circuit on which the replace is to
be installed has the power cut off
at the service panel until installa-
tion is complete.
3. Remove the partially reective
glass from the replace:
• Lay replace on its back.
• Remove two Phillips screws
from each of the two glass
brackets (Figure 2, page 8).
• Remove glass brackets.
• With one hand keeping pres-
sure on the partially reective
glass, tilt the replace upright
and slightly forward to allow
the partially reective glass to
fall out of the inside framing.
CAUTION: Partially reective
glass is not tempered. Do not
bump or drop the partially reec-
tive glass to avoid breakage and
personal injury.
• Remove partially reective