7
Site Selection
Review and consider all of the fol-
lowing conditions for installation:
• Dimensions of the unit: 50
5
/
16
"
(128cm) x 19½"(49.5cm)
• Unit requires a minimum of two
wall studs in order to ensure a
secure installation
There are three possible mount-
ing methods:
• Surface mount (pg. 11);
• In-wall Recessed (pg. 13);
• Flush mount (pg. 14),
and any of these have the option
of being hard-wired or plugged
directly into the wall outlet.
!
NOTE:If the desired replace
location is on the interior of an ex-
terior wall the unit should only be
surface mounted. If an in-wall or
ush mount look is desired build
the interior wall out into the room.
!
NOTE 1: A 15 Amp, 120 Volt
circuit is required. A dedicated
circuit is preferred but not essen-
tial in all cases. A dedicated circuit
will be required if, after installa-
tion, the circuit breaker trips or
fuse blows on a regular basis
when the heater is operating. Ad-
ditional appliances on the same
circuit may exceed the current
Fireplace Installation
rating of the circuit breaker.
WARNING: Ensure the power
cord is not installed so that it
is pinched or against a sharp
edge and ensure that the
power cord is stored or secured
to avoid tripping or snagging to
reduce the risk of re, electric
shock or injury to persons.
Construction and electrical
outlet wiring must comply
with local building codes and
other applicable regulations to
reduce the risk of re, electric
shock and injury to persons.
WARNING: To reduce the risk
of re, do not store or use gaso-
line, or other ammable vapors or
liquids in the vicinity of the heater.
1. Select a location that is not
susceptible to moisture and
is away from drapes, furniture
and high trafc.
2. For ease of electrical hook up
you may wish to locate the
replace near an existing outlet
(for plug-in convenience) (refer
to NOTE 1).
3. Remove replace, front glass
and hardware from box and
remove all packaging materials
before installation.