Questions and Answers

  • O
    oconnorandreaSep 23, 2025
    Why is my Dimplex CDFI1000-PRO making noise on standby?
    • W
      William JenkinsSep 23, 2025
      Some buzzing is normal for Dimplex Indoor Fireplace when the unit is on standby. However, if there is excessive noise, replace the power supply.
  • D
    David WilsonAug 25, 2025
    What to do if my Dimplex Electric Heater does not turn on with the remote control?
    • J
      Joseph WalshAug 25, 2025
      If your Dimplex Electric Heater isn't turning on with the remote control, the remote control might not be initialized to the tethered controller. Please, follow the initialization instructions in the ‘Operation’ section. Another possible reason is that the batteries in the remote are dead. Try replacing them.
  • B
    Barbara WilsonAug 25, 2025
    Why is my Dimplex Electric Heater unit continuously blinking four times?
    • G
      Gina JonesAug 26, 2025
      If your Dimplex Electric Heater is continuously blinking four times, it means the fill cycle has timed out. Turn the unit off using the power switch, wait 10 seconds, and then turn it back on. If the problem continues, clean the water filter and check the plumbing to ensure adequate pressure and that nothing is blocking water flow.
  • E
    erika46Aug 27, 2025
    What to do if my Dimplex Electric Heater unit continuously blinks one time?
    • K
      Kyle GonzalezAug 27, 2025
      If your Dimplex Electric Heater is continuously blinking one time, it indicates that the water level in the sump is too high. To resolve this, turn off the unit using the power switch and remove enough water from the reservoir until the level is below the maximum.
  • D
    Dr. David Gilbert Jr.Sep 23, 2025
    What does three blinks mean on my Dimplex CDFI1000-PRO?
    • B
      Brittany PetersonSep 23, 2025
      If your Dimplex Indoor Fireplace unit continuously blinks three times, the level sensor assembly may be defective and needs to be replaced.
  • W
    Whitney FloydSep 13, 2025
    Why does my Dimplex CDFI1000-PRO Indoor Fireplace smell bad?
    • C
      Catherine Kline MDSep 13, 2025
      If you notice an unpleasant smell when using your Dimplex Indoor Fireplace, it might be due to dirty or stale water. Clean the unit as described under the Maintenance section.
  • M
    Marie KeySep 12, 2025
    What does two blinks mean on my Dimplex CDFI1000-PRO Indoor Fireplace?
    • G
      George GreenSep 12, 2025
      If your Dimplex Indoor Fireplace unit continuously blinks twice, refill the water reservoir so that the level is above the minimum level.
  • S
    Shelley SimsSep 12, 2025
    What does one blink mean on my Dimplex CDFI1000-PRO?
    • K
      Kim HerreraSep 12, 2025
      If your Dimplex Indoor Fireplace unit continuously blinks one time, remove enough water from the reservoir so that the level is below the maximum level.
  • D
    Douglas KennedySep 4, 2025
    What to do if water is appearing beneath Dimplex CDFI1000-PRO?
    • R
      Rebecca MaxwellSep 4, 2025
      If water is appearing around your Dimplex Indoor Fireplace, ensure that all water connections are tight and fully inserted to prevent leaks. Also, reduce the water pressure to below 58 psi (8 bar) if the incoming water pressure is too high.
  • D
    donna05Sep 1, 2025
    Why is the flame effect too low on my Dimplex Indoor Fireplace?
    • W
      williamweaverSep 1, 2025
      If the flame effect is too low in your Dimplex Indoor Fireplace, first, adjust the flame height on both the secondary and/or primary controls, as the flame effect control may be set too low. If that doesn't work, check for insufficient air intake and enlarge the area for air to enter the unit, ensuring it reaches the bottom. A defective transducer could also be the cause, so consider replacing it.

Summary

IMPORTANT INSTRUCTIONS

Safety Warnings and Notes

Summarizes critical safety warnings, notes, and cautions for safe operation and compliance.

Installation

Cassette Plumbing

Details the process for hardwiring the cassette to a water supply.

Electrical Wiring

Explains the electrical connection process for the unit's power supply.

Bathroom Installation

Specific safety precautions for installing the unit in a bathroom environment.

Operation

Control Functions Overview

Explains the functions of the unit's various control buttons and modes.

Maintenance

Warranty Information

Dimplex CDFI1000-PRO Specifications

General IconGeneral
ModelCDFI1000-PRO
CategoryIndoor Fireplace
TypeElectric Fireplace
Heating CapacityUp to 400 sq. ft.
Heating Area400 sq. ft.
Flame EffectYes
Remote ControlYes
Adjustable ThermostatYes
Overheat ProtectionYes
Voltage120V
Heat Output1000W
Wattage1000W
BTUs3412 BTUs
ControlRemote Control
Power SupplyElectric
Dimensions23.5" W
InstallationInsert