Owners Manual
6909660300
6909660400
Model
CDFI1000-PRO
CDFI500-PRO
7214300200R00
IMPORTANT SAFETY INFORMATION: Always read this manual
rst before attempting to install or use the Opti-myst
®
cassette. For
your safety, always comply with all warnings and safety instructions
contained in this manual to prevent personal injury or property
damage.
To view the full line of Dimplex products, please visit
www.dimplex.com

Other manuals for Dimplex CDFI1000-PRO

Questions and Answers

  • M
    Marie KeySep 12, 2025
    What does two blinks mean on my Dimplex CDFI1000-PRO Indoor Fireplace?
    • G
      George GreenSep 12, 2025
      If your Dimplex Indoor Fireplace unit continuously blinks twice, refill the water reservoir so that the level is above the minimum level.
  • B
    Brian CooperSep 9, 2025
    What does four blinks mean on my Dimplex Indoor Fireplace?
    • M
      Melissa AndersonSep 10, 2025
      If your Dimplex Indoor Fireplace unit continuously blinks four times, turn the unit off with the main power switch and wait 60 seconds before turning it back on. If the problem persists, clean the water filter and inspect the plumbing to ensure the pressure is adequate and nothing is obstructing water flow.
  • K
    Kevin MoonSep 8, 2025
    Why won't the flame effect start on my Dimplex CDFI1000-PRO Indoor Fireplace?
    • P
      Patricia CoxSep 8, 2025
      If the Dimplex Indoor Fireplace flame effect will not start and there are no error blinks, note that mist will begin emitting after 45 seconds of operation. If flame is being produced but is not rising beyond the top cover, lift the top cover carefully while the unit is operating. If mist is produced but not rising, refer to section 3.5. Also, put the unit in test mode to test the transducer; if the transducer is running, ensure the emitter is clean and free of calcium deposits or scaling. If the transducer is not running, replace it with the provided additional transducer.
  • B
    browningandrewSep 7, 2025
    Why doesn't mist rise in my Dimplex Indoor Fireplace?
    • J
      Jeffrey CallahanSep 7, 2025
      If mist is being produced under the top cover of your Dimplex Indoor Fireplace but does not rise to create a flame effect, make sure the cord is not located over the emitter on the transducer; relocate it so the mist can rise freely. Ensure the transducer is correctly installed, with the connection clicked into place and the transducer seated properly. Also, check for water in the fan duct and ensure there is none. Put the unit in test mode to test the fan, ensuring the fan filter is clean and dry. If the fan isn't working in test mode, replace it; if the issue persists, replace the main board.
  • K
    Kristina DavisAug 23, 2025
    How to fix Dimplex Electric Heater if it does not turn on with the onboard controls?
    • Z
      zdaltonAug 23, 2025
      If your Dimplex Electric Heater doesn't turn on with the onboard controls, there might be a few reasons. First, ensure the unit is correctly wired and has incoming power. Next, check that the power switch is in the 'on' position (I). Finally, make sure you've pressed the standby button until you hear one beep to activate the flame effect.
  • J
    Jeremy MclaughlinSep 5, 2025
    Why is the flame rolling back into my Dimplex CDFI1000-PRO Indoor Fireplace?
    • J
      Justin WolfeSep 5, 2025
      If the flame appears to be rolling back into your Dimplex Indoor Fireplace, ensure there is sufficient air intake by enlarging the area for air to enter the unit, making sure it reaches the bottom. If that's not the issue, put the unit in test mode to check the operation of the heating element. If no click is heard from the relay, replace the main board.
  • D
    Douglas KennedySep 4, 2025
    What to do if water is appearing beneath Dimplex CDFI1000-PRO?
    • R
      Rebecca MaxwellSep 4, 2025
      If water is appearing around your Dimplex Indoor Fireplace, ensure that all water connections are tight and fully inserted to prevent leaks. Also, reduce the water pressure to below 58 psi (8 bar) if the incoming water pressure is too high.
  • B
    Brandon GarciaSep 3, 2025
    How to fix uneven mist on a Dimplex CDFI1000-PRO?
    • M
      Monica HaleSep 3, 2025
      If mist is not coming out evenly from your Dimplex Indoor Fireplace, you can take the following steps: * Remove any condensation buildup on the mist outlet. * Adjust the feet under the unit to ensure it is level, front to back and side to side. * Rearrange the media to ensure it is not blocking airflow. * If the transducer is running in test mode, ensure that the emitter is clean and free of calcium deposits or scaling. If it is not running, replace the transducer with the provided additional transducer. * If you are using demineralized water, add 1/8 tsp of table salt to the water reservoir to introduce electrolytes, repeating only when mist is not being produced correctly. * Allow water to warm to room temperature.
  • D
    donna05Sep 1, 2025
    Why is the flame effect too low on my Dimplex Indoor Fireplace?
    • W
      williamweaverSep 1, 2025
      If the flame effect is too low in your Dimplex Indoor Fireplace, first, adjust the flame height on both the secondary and/or primary controls, as the flame effect control may be set too low. If that doesn't work, check for insufficient air intake and enlarge the area for air to enter the unit, ensuring it reaches the bottom. A defective transducer could also be the cause, so consider replacing it.
  • L
    leachalexandraAug 31, 2025
    How to reduce smoke in Dimplex Indoor Fireplace flame effect?
    • D
      Diane DelgadoSep 1, 2025
      If the flame effect in your Dimplex Indoor Fireplace has too much smoke or is coming out too fast, it could be due to the flame effect control being set too high. Adjust the flame height on both the secondary and/or primary controls to reduce the smoke or speed. Also, check if the filter is missing from the fan housing and insert the fan filter if it is missing.

Summary

IMPORTANT INSTRUCTIONS

Safety Warnings and Notes

Summarizes critical safety warnings, notes, and cautions for safe operation and compliance.

Installation

Cassette Plumbing

Details the process for hardwiring the cassette to a water supply.

Electrical Wiring

Explains the electrical connection process for the unit's power supply.

Bathroom Installation

Specific safety precautions for installing the unit in a bathroom environment.

Operation

Control Functions Overview

Explains the functions of the unit's various control buttons and modes.

Maintenance

Warranty Information

Dimplex CDFI1000-PRO Specifications

General IconGeneral
ModelCDFI1000-PRO
CategoryIndoor Fireplace
TypeElectric Fireplace
Heating CapacityUp to 400 sq. ft.
Heating Area400 sq. ft.
Flame EffectYes
Remote ControlYes
Adjustable ThermostatYes
Overheat ProtectionYes
Voltage120V
Heat Output1000W
Wattage1000W
BTUs3412 BTUs
ControlRemote Control
Power SupplyElectric
Dimensions23.5" W
InstallationInsert

Related product manuals