Model
CDFI1000P
6909660100
7214300100R04
IMPORTANT SAFETY INFORMATION: Always read this manual rst
before attempting to install or use the wall mount unit. For your safety,
always comply with all warnings and safety instructions contained in
this manual to prevent personal injury or property damage.
To view the full line of Dimplex products, please visit
www.dimplex.com

Other manuals for Dimplex CDFI1000P

Questions and Answers

  • K
    Keith LiSep 18, 2025
    What does it mean when my Dimplex Indoor Fireplace is blinking every 8 seconds?
    • S
      Scott DavidSep 18, 2025
      If your Dimplex Indoor Fireplace is blinking every 8 seconds and not operating, it could be due to: water level in reservoir is too high, remove enough water from reservoir so that level is below maximum level; if the solenoids are not working, replace the solenoid.
  • R
    Rachel FrancisAug 25, 2025
    Why won't my Dimplex CDFI1000P turn on with the remote?
    • I
      ilewisAug 25, 2025
      If your Dimplex Indoor Fireplace does not turn on with the remote control, first, consult the Operation Section to ensure proper operation. Then, try installing new batteries in the remote control. Make sure the tethered controller is correctly installed, ensuring the connection has clicked into place and a red light is visible. Synchronize the remote to the unit; the unit will flash on and off during synchronization, and completion will be indicated with 5 beeps. Ensure the tethered controller is in an open area to receive the remote signal. If the blue light on the remote doesn't turn on when buttons are pressed, the remote control may be defective and needs replacement.
  • M
    Margaret EllisonAug 25, 2025
    How to reduce smoke in Dimplex CDFI1000P Indoor Fireplace flame effect?
    • B
      barbarawilliamsAug 26, 2025
      If the flame effect in your Dimplex Indoor Fireplace has too much smoke or is coming out too fast, it could be due to the flame effect control being set too high. Adjust the flame height on both the secondary and/or primary controls to reduce the smoke or speed. Also, check if the filter is missing from the fan housing and insert the fan filter if it is missing.
  • G
    George MartinAug 26, 2025
    Why is the flame effect too low on my Dimplex CDFI1000P Indoor Fireplace?
    • W
      walshalexanderAug 27, 2025
      If the flame effect is too low in your Dimplex Indoor Fireplace, first, adjust the flame height on both the secondary and/or primary controls, as the flame effect control may be set too low. If that doesn't work, check for insufficient air intake and enlarge the area for air to enter the unit, ensuring it reaches the bottom. A defective transducer could also be the cause, so consider replacing it.
  • L
    lisa12Sep 22, 2025
    How to get rid of the smell from my Dimplex Indoor Fireplace?
    • R
      rdelgadoSep 22, 2025
      If you notice an unpleasant smell when using your Dimplex Indoor Fireplace, it might be due to dirty or stale water. Clean the unit as described under maintenance.
  • J
    jennaflynnSep 23, 2025
    What to do if LED lights don't come on my Dimplex CDFI1000P?
    • T
      traviswarnerSep 23, 2025
      If the LED lights on your Dimplex Indoor Fireplace don't come on when the unit is turned on, replace LED Light strip.
  • D
    Deanna OliverSep 8, 2025
    How to fix a Dimplex CDFI1000P Indoor Fireplace sump not filling?
    • R
      Renee SanchezSep 9, 2025
      If your Dimplex Indoor Fireplace sump is not filling from the refill bottle, ensure the unit is level. Place something under the bottle to slope it slightly toward the fill cap so that the water can easily flow to the water reservoir.
  • M
    Mark FrenchSep 9, 2025
    Why is my Dimplex CDFI1000P Indoor Fireplace not refilling and not showing error blinks?
    • J
      Juan StevensSep 10, 2025
      If your Dimplex Indoor Fireplace unit is not refilling and is not giving error blinks when the water is too high or too low, the level sensor assembly may be defective and needs to be replaced.
  • M
    Michelle MillerSep 3, 2025
    What does two blinks mean on my Dimplex Indoor Fireplace?
    • J
      josephcrossSep 3, 2025
      If your Dimplex Indoor Fireplace unit continuously blinks twice, refill the water reservoir so that the level is above the minimum level.
  • D
    David MoralesSep 1, 2025
    Why won't the flame effect start on my Dimplex CDFI1000P?
    • J
      Jennifer SmithSep 1, 2025
      If the Dimplex Indoor Fireplace flame effect will not start and there are no error blinks, note that mist will begin emitting after 45 seconds of operation. If flame is being produced but is not rising beyond the top cover, lift the top cover carefully while the unit is operating. If mist is produced but not rising, refer to section 3.5. Also, put the unit in test mode to test the transducer; if the transducer is running, ensure the emitter is clean and free of calcium deposits or scaling. If the transducer is not running, replace it with the provided additional transducer.

Summary

Owners Manual - Safety Information

Welcome & Congratulations

Important Instructions

Important Instructions - FCC Compliance

Installation

Cassette Plumbing

Instructions for plumbing the unit using a kit or standard tubing, ensuring local code compliance.

Installation - New Construction

Installation - Electrical and Dimensions

Installation - Wiring and Securing

Operation Preparation

Steps for preparing the unit for operation, including removing the media plate and installing the controller.

Installation - Mist Production and Accessories

Installation - Bathroom Installation and Wiring Diagram

Operation

Controls

Description of the primary controls like On/Off switch and module adjustments for flame effect.

Operation - Control Details

Operation - Remote Control and Battery Replacement

Maintenance

Filling the Water Tank

Step-by-step guide on how to refill the unit's water tank, with cautions for cooling and cap tightening.

Maintenance - Cleaning and Servicing

Accessories

Information on purchasing genuine Dimplex accessories such as logsets and piercing kits.

Warranty

Warranty - What Dimplex Does

Warranty - Limitations and Legal

Dimplex CDFI1000P Specifications

General IconGeneral
ModelCDFI1000P
CategoryIndoor Fireplace
TypeElectric
Product TypeFireplace Insert
Voltage120V
Heating AreaUp to 400 sq. ft.
StyleTraditional
FinishBlack
Flame EffectYes
Flame TechnologyLED
Flame ColorMulti-color
Adjustable ThermostatYes
Overheat ProtectionYes
InstallationInsert
Wattage1000W
BTUs1, 000 BTUs
Control TypeRemote Control
Height23.5 in

Related product manuals