Installation
The CDFI1000 is supplied in an
assembled state and is designed to
be permanently installed. The unit
comes ready for hardwire installa-
tion and the use of the water rell
containers.
WARNING: Construction and
electrical outlet wiring must
comply with local building codes
and other applicable regulations
to reduce the risk of re, electric
shock and injury to persons.
WARNING: To reduce the risk of
re, do not store or use gaso-
line or other ammable vapours
or liquids in the vicinity of the
heater.
!
NOTE: A 15 Amp, 120 Volt cir-
cuit is required. A dedicated circuit
is preferred but not essential in all
cases. A dedicated circuit will be
required if, after installation, the cir-
cuit breaker trips or the fuse blows
on a regular basis when the heater
is operating. Additional appliances
on the same circuit may exceed the
current rating of the circuit breaker.
WARNING: Failure to install the
cassette as instructed below
may result in damage to the
equipment and or may expose
the user to the risk of re, ser-
ious injury, illness or death.
WARNING: Do not attempt to
wire your own new outlets or
circuits. To reduce the risk of
re, electric shock or injury to
persons, always use a licensed
electrician.
WARNING: Ensure that the
On/Off switch is set to the Off
position (refer to Operation
section) and that the circuit on
which the unit is to be installed
has the power cut off at the
service panel until installation is
complete.
!
NOTE: Please read all instruc-
tions before installing.
Cassette Plumbing
The unit comes equipped with rell
containers for manual lling of the
reservoir. The unit can be hard
plumbed with the Dimplex plumbing
accessory kit - available from your
local Dimplex dealer, or with stan-
dard 1/4 in. (6.4 mm) tubing, using
the information outlined below.
!
NOTE: The plumbing accessory
kit is designed for use with copper
piping.
CAUTION: Ensure that all
plumbing connections meet local
plumbing code requirements.
CAUTION: Ensure that the
location of the plumbing connection
allows for easy access to allow for
shutoff during scheduled mainten-