Owners Manual
Model
CDFI1000P
6909660100
7214300100R04
IMPORTANT SAFETY INFORMATION: Always read this manual rst
before attempting to install or use the wall mount unit. For your safety,
always comply with all warnings and safety instructions contained in
this manual to prevent personal injury or property damage.
To view the full line of Dimplex products, please visit
www.dimplex.com

Other manuals for Dimplex CDFI1000P

Questions and Answers

  • D
    David MoralesSep 1, 2025
    Why won't the flame effect start on my Dimplex CDFI1000P?
    • J
      Jennifer SmithSep 1, 2025
      If the Dimplex Indoor Fireplace flame effect will not start and there are no error blinks, note that mist will begin emitting after 45 seconds of operation. If flame is being produced but is not rising beyond the top cover, lift the top cover carefully while the unit is operating. If mist is produced but not rising, refer to section 3.5. Also, put the unit in test mode to test the transducer; if the transducer is running, ensure the emitter is clean and free of calcium deposits or scaling. If the transducer is not running, replace it with the provided additional transducer.
  • W
    wcostaAug 31, 2025
    Why doesn't mist rise in my Dimplex Indoor Fireplace?
    • J
      Jesse HansonAug 31, 2025
      If mist is being produced under the top cover of your Dimplex Indoor Fireplace but does not rise to create a flame effect, make sure the cord is not located over the emitter on the transducer; relocate it so the mist can rise freely. Ensure the transducer is correctly installed, with the connection clicked into place and the transducer seated properly. Also, check for water in the fan duct and ensure there is none. Put the unit in test mode to test the fan, ensuring the fan filter is clean and dry. If the fan isn't working in test mode, replace it; if the issue persists, replace the main board.
  • M
    marcusloganAug 30, 2025
    Why is my Dimplex CDFI1000P Indoor Fireplace underfilling when plumbed to a water source?
    • R
      Raymond RamirezAug 30, 2025
      If your Dimplex Indoor Fireplace unit is underfilling or not filling, and it's hard plumbed to a water source, first ensure that the unit is level to allow an accurate reading of the water level. Check that the ball valve of the unit is open and water is getting to the unit. Inspect the sump to ensure floats are installed. If these steps don't resolve the issue, the level sensor assembly may be defective and require replacement. Also, put the unit in test mode to test the operation of the solenoids; if they are not working, replace the solenoid.
  • A
    Amy RogersAug 29, 2025
    Why is the flame rolling back into my Dimplex CDFI1000P Indoor Fireplace?
    • D
      Dr. Valerie SmithAug 29, 2025
      If the flame appears to be rolling back into your Dimplex Indoor Fireplace, ensure there is sufficient air intake by enlarging the area for air to enter the unit, making sure it reaches the bottom. If that's not the issue, put the unit in test mode to check the operation of the heating element. If no click is heard from the relay, replace the main board.
  • B
    becky92Aug 28, 2025
    What to do if water is appearing beneath Dimplex CDFI1000P Indoor Fireplace?
    • A
      Ashley JuarezAug 28, 2025
      If water is appearing around your Dimplex Indoor Fireplace, ensure that all water connections are tight and fully inserted to prevent leaks. Also, reduce the water pressure to below 58 psi (8 bar) if the incoming water pressure is too high.
  • A
    Andrew NavarroAug 27, 2025
    How to fix uneven mist on a Dimplex CDFI1000P?
    • S
      stewarthectorAug 27, 2025
      If mist is not coming out evenly from your Dimplex Indoor Fireplace, you can take the following steps: * Remove any condensation buildup on the mist outlet. * Adjust the feet under the unit to ensure it is level, front to back and side to side. * Rearrange the media to ensure it is not blocking airflow. * If the transducer is running in test mode, ensure that the emitter is clean and free of calcium deposits or scaling. If it is not running, replace the transducer with the provided additional transducer. * If you are using demineralized water, add 1/8 tsp of table salt to the water reservoir to introduce electrolytes, repeating only when mist is not being produced correctly. * Allow water to warm to room temperature.
  • G
    George MartinAug 26, 2025
    Why is the flame effect too low on my Dimplex CDFI1000P Indoor Fireplace?
    • W
      walshalexanderAug 27, 2025
      If the flame effect is too low in your Dimplex Indoor Fireplace, first, adjust the flame height on both the secondary and/or primary controls, as the flame effect control may be set too low. If that doesn't work, check for insufficient air intake and enlarge the area for air to enter the unit, ensuring it reaches the bottom. A defective transducer could also be the cause, so consider replacing it.
  • M
    Margaret EllisonAug 25, 2025
    How to reduce smoke in Dimplex CDFI1000P Indoor Fireplace flame effect?
    • B
      barbarawilliamsAug 26, 2025
      If the flame effect in your Dimplex Indoor Fireplace has too much smoke or is coming out too fast, it could be due to the flame effect control being set too high. Adjust the flame height on both the secondary and/or primary controls to reduce the smoke or speed. Also, check if the filter is missing from the fan housing and insert the fan filter if it is missing.
  • R
    Rachel FrancisAug 25, 2025
    Why won't my Dimplex CDFI1000P turn on with the remote?
    • I
      ilewisAug 25, 2025
      If your Dimplex Indoor Fireplace does not turn on with the remote control, first, consult the Operation Section to ensure proper operation. Then, try installing new batteries in the remote control. Make sure the tethered controller is correctly installed, ensuring the connection has clicked into place and a red light is visible. Synchronize the remote to the unit; the unit will flash on and off during synchronization, and completion will be indicated with 5 beeps. Ensure the tethered controller is in an open area to receive the remote signal. If the blue light on the remote doesn't turn on when buttons are pressed, the remote control may be defective and needs replacement.

Summary

Owners Manual - Safety Information

Welcome & Congratulations

Important Instructions

Important Instructions - FCC Compliance

Installation

Cassette Plumbing

Instructions for plumbing the unit using a kit or standard tubing, ensuring local code compliance.

Installation - New Construction

Installation - Electrical and Dimensions

Installation - Wiring and Securing

Operation Preparation

Steps for preparing the unit for operation, including removing the media plate and installing the controller.

Installation - Mist Production and Accessories

Installation - Bathroom Installation and Wiring Diagram

Operation

Controls

Description of the primary controls like On/Off switch and module adjustments for flame effect.

Operation - Control Details

Operation - Remote Control and Battery Replacement

Maintenance

Filling the Water Tank

Step-by-step guide on how to refill the unit's water tank, with cautions for cooling and cap tightening.

Maintenance - Cleaning and Servicing

Accessories

Information on purchasing genuine Dimplex accessories such as logsets and piercing kits.

Warranty

Warranty - What Dimplex Does

Warranty - Limitations and Legal

Dimplex CDFI1000P Specifications

General IconGeneral
ModelCDFI1000P
CategoryIndoor Fireplace
TypeElectric
Product TypeFireplace Insert
Voltage120V
Heating AreaUp to 400 sq. ft.
StyleTraditional
FinishBlack
Flame EffectYes
Flame TechnologyLED
Flame ColorMulti-color
Adjustable ThermostatYes
Overheat ProtectionYes
InstallationInsert
Wattage1000W
BTUs1, 000 BTUs
Control TypeRemote Control
Height23.5 in