www.dimplex.de 452172.66.10-EN · FD 0311 EN-41
LIA 0608BWCF M - LIA 1316BWCF M English
15 Product information as per
Regulation (EU) No 813/
2013, Annex II, Table 2
Information requirements for heat pump space heaters and heat pump combination heaters
Item Symbol Value Unit Item Symbol Value
Pdh
5,05 kW Tj = - 7°C
COPd
2,17 -
Pdh
3,12 kW Tj = + 2°C
COPd
3,51 -
Pdh
2,09 kW Tj = + 7°C
COPd
4,54 -
Pdh
1,28 kW Tj = + 12°C
COPd
5,59 -
Tj = bivalent temperature
Pdh
5,05 kW Tj = bivalent temperature
COPd
2,17 -
Tj = operation limit temperature
Pdh
4,52 kW Tj = operation limit temperature
COPd
1,91 -
For air-to-water heat pumps
For air-to-water heat pumps:
Tj = -15°C (if TOL < -20°C)
Pdh
/ kW Tj = -15°C (if TOL < -20°C)
COPd
/-
For air-to-water heat pumps:
Operation limit temperature
Cycling interval capacity for heating
Pcych
-kW
Cycling interval efficiency COPcyc
--
Degradation co-efficient (**)
Heating water operating limit
temperature
Power consumption in modes other than active mode
P
OFF
0,014
kW Rated heat output (*)
Psup
1,18 kW
P
TO
0,024
kW
Type of energy input
eletrical
Crankcase heater mode
P
CK
0,000
kW
m³ /h
Sound power level, indoors/ outdoors
Emissions of nitrogen oxides
XL
Water heating energy efficiency
η
wh
116 %
Daily electricity consumption
Q
elec
6,79 kWh Daily fuel consumption
Q
fuel
-
(**) If Cdh is not determined by measurement nthen the default degradation is Cdh = 0,9
For air-to-water heat pumps: Rated
air flow rate, outdoors
For water-/brine-to-water heat
pumps: Rated brine or water flow
rate, outdoor heat exchanger
Declared capacity for heating foer part load at indoor temperature 20°C and
outdoor temperature Tj
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20 °C and outdoor temperature Tj
For heat pump combination heater:
Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach
(*) For heat pump space heaters and heat pump combination heaters, the rated output Prated is equal to the design load for heating Pdesignh , and the rated
heat output of a supplementary capacity for heating sup(Tj ).
Heat pump combination heater
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low- temperature heat pumps, parameters
shall be declared for low-temperature application.
Seasonal space heating energy
efficiency
Parameters shall be declared for average climate conditions:
Low-temperature heat pump
Equipped with a supplementary heater
Dimplex LIA 0608BWCF M (LIA 0608 M + LIA BW)