52
OPERATOR’S MANUAL with Maintenance Information
Maintenance
machine is functioning properly
¤ Result: The alarm does not sound.
Calibrate the platform overload system.
6 Lower the platform onto the safety arm.
Crushing hazard. Keep
hands clear of the safety arm when lowering
the platform.
7 Install the up limited switch.
8 Raise the platform and return the safety
arm to the stowed position.
9 Fully raise the platform. Release thetoggle
switch.
Result -The alarm should not sound. The
system is functioning correctly.
¤ Result: The alarm sounds. The system is
not functioning correctly. Troubleshoot the
limit switch, limit switch wire harness or
limit switch mount bracket OR the platform
overload system needs to be calibrated.
10 Lower the platform to the stowed position.