EasyManua.ls Logo

Dini Argeo MCWN Series - TROUBLESHOOTING CASES

Dini Argeo MCWN Series
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MCWN
47
Troubleshooting cases
USER_MAN_ENG_MCWN
TROUBLESHOOTING CASES
TARE
The scale does
not tare
The weight is unstable (unStAb)
The gross weight is negative (loW)
The weight is insufficient
The weight exceeds the maximum capacity
The tare function has been disabled
With manual tare, the value exceeds the maximum capacity
WEIGHING
The scale does
not switch on
Check the correct insertion of the battery holder.
Replace the battery and try again. If the instrument continues to malfunc-
tion, contact the dealer.
The scale switches
o suddenly
Automatic switch-off enabled
Low battery
Power supply line failure
The scale is
not reactive
One of the available energy saving modes has been enabled
An unsuitable weighing filter has been selected
The scale screen
switches o and
displays a dot
Stand-by mode is enabled: press a key to re-enable weighing.
Energy saving mode is enabled: contact the dealer for further details.
The scale displays
a permanent “Zero
message
The scale is unable to automatically reset the weight because it exceeds
the maximum resettable weight at switch-on.
Release the hook and try again. If the scale continues to have the same
problem even when the hook is unloaded, contact the dealer.
The weight is
unstable
Check whether the weighing filter is enabled.
If the system is subjected to vibrations from machinery or moving vehi-
cles, move the scale onto another surface and try again.

Related product manuals