ANDIAMO.MC Hardware Guide - Version 2.0
CHAPTER 4: Operation
Matrix Mode
Channel based routing can be set up via remote control (ANDIAMO Remote). Each
output can be assembled individually from any input sources.
A subset of the Matrix Mode is the Extended Routing feature. It is switchable and
enables both MADI I/Os to be used independently to:
• make full use of all conversion channels at higher sample rates
• double the range of available MADI input channels
• create two individual MADI feeds
The settings of the routing matrix are stored inside the device.
It is possible to toggle between Standard Bank Routing and Matrix Mode without
using the remote control. See „CHAPTER 5: Menu Navigation“ on page 42.
LED Code Mode
Both LEDs on.
Matrix Mode active.
Extended Routing not active.
Both MADI outputs work in parallel.
Delay compensation not active.
2 x
Both LEDs blinking heartbeat.
Matrix Mode active
Extended Routing not active
Both MADI outputs work in parallel.
Delay compensation active.
Both LED columns blinking alternately.
Matrix Mode active
Extended Routing active
MADI outputs may transmit individual signals.
Delay compensation not active.
2 x 2 x
Both LED columns blinking two times alternately.
Matrix Mode active
Extended Routing active
MADI outputs may transmit individual signals.
Delay compensation active.