page 36 of 72 ANDIAMO.MC Hardware Guide - Version 2.0
CHAPTER 4: Operation
Delay Compensation
For conversion of all 64 channels (@ 1 FS) of a MADI signal two ANDIAMOs may
be daisy-chained. Between MADI input and output there is a delay of four samples.
To ensure phase locked operation of all audio channels the delay between the two
ANDIAMOs will be compensated then.
Delay compensation becomes active, once an ANDIAMO ‘sees’ another
ANDIAMO at its input. The ‘second’ ANDIAMO will switch to ID 02.
Delay compensation:
Δt A/D Δt D/A
ID 01 0 + 4 samples
ID 02 + 4 samples 0
NOTE
To ensure proper detection of delay compensation no other device must be
connected in between two ANDIAMOs.
Delay compensation may be deactivated in the ANDIAMO Remote.
ANDIAMO - ID 01 ANDIAMO - ID 02
OUT IN
Δt = 4 samples