EasyManua.ls Logo

Distinction PASRW030-BP2 - 2. SPECIFICATION; 2.1 Performance data of swimming pool heat pump unit; 2.2 Dimensions for swimming pool heat pump unit

Distinction PASRW030-BP2
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2
2. SPECIFICATION
2.1 Performance data of swimming pool heat pump unit
REFRIGERANT : R410A
UNIT PASRW030-BP2 PASRW040-BP2
*Rated heating power input (95 Hz) kW 2.32 3.13
*Range
kW 0.25 - 2.32 0.24 - 3.13
*Rated running current input (95 Hz) A 10.0 13.6
*Range
A
1.08 - 10.0
1.04 - 13.6
**Rated heating power input (95 Hz) kW 2.15 2.77
**Range kW 0.29 - 2.15 0.35 - 2.77
**Rated running current input (95 Hz) A 9.34 12.0
**Range A 1.26 - 9.34 1.52 - 12.0
Power supply 208-230V - 60 Hz 208-230V - 60 Hz
Compressor Quantity 1 1
Compressor Rotary Rotary
Fan quantity 1 1
Fan power input W 100 100
Fan rotate speed RPM 500-650 500 - 700
Fan direction Horizontal Horizontal
Noise dB (A) 43 - 53
44 - 54
Water connection Inch 1.5 1.5
Water flow volume g/min 18.0 22.9
Water pressure drop (max) kPa 4 5
Unit net dimensions (L/W/H) Mm See the drawing of the units
Unit ship dimensions (L/W/H) Mm See package label
Net weight Kg See name plate
Shipping weight Kg See package label
Rated heating
*Outdoor air temp : 80.6°F (27°C) / 75.8°F (24.3°C), Inlet/Outlet water temp : 80°F (26.7°C) / 84.7°F (29.3°C)
**Outdoor air temp : 59°F (15°C) / 53.6°F (12°C), Inlet/Outlet water temp : 78.8°F (26°C) / 82.4°F (28°C)
During heating : running ambient temperature : 23°F (-5°C) - 109.4°F (43°C)
Visit www.ahridirectory.org for full Distinction Heat Pump Performance Data