19
IP2162EN
EN
Display Description
OB - Adjustment of deceleration distance during
closing. [cm]
Indicates the distance from the end of the closing
stroke where the deceleration ramp begins.
05 - Minimum , (20 - Neos Super Fast)
99 - Maximum
N.B.: reduce the deceleration space if there is a series
of quick vibrations (chattering) in heavy gates installed
with a slight incline.
40
Neos Super Fast
99
PO - Adjustment of approach speed during opening.
[cm/s]
Indicates the speed from the end of the deceleration
ramp to the end of the stroke.
02 - Minimum
10 - Maximum
N.B.: gradually increase the approach speed if there is
a series of quick vibrations (chattering) in heavy gates
installed with a slight incline.
03
05
(Neos Super Fast)
PC - Adjustment of approach speed during closing.
[cm/s]
Indicates the speed from the end of the deceleration
ramp to the end of the stroke.
02 - Minimum
10 - Maximum
N.B.: gradually increase the approach speed if there is
a series of quick vibrations (chattering) in heavy gates
installed with a slight incline.
03
05
(Neos Super Fast)
OO - Obstacle detection limit during opening [cm]
Indicates the distance from the end of the opening
stroke after which each obstacle is considered a stop.
05 - Minimum
99 - Maximum
N.B.: This parameter is only active if
40
OC - Obstacle detection limit during closing [cm]
Indicates the distance from the end of the closing
stroke after which each obstacle is considered a stop.
05 - Minimum
99 - Maximum
N.B.: This parameter is only active if
40
i
N.B.: make adjustments gradually and only after performing at least three complete
operations to allow the control panel to be set correctly and detect any friction during
operations.
BA