30
IP2162EN
EN
Display Description
TN - Setting of intervention temperature for NIO anti-
freeze system. [°C]
Adjustment of the working temperature of the control pan-
el. The value does not refer to ambient temperature.
5
TB - Display of working temperature of control panel.
DO NOT USE
WO - Setting of pre-flashing time on opening. [s]
Adjustment of the lead time for the switch-on of the
ashing light, in relation to the start of the opening op-
eration from a voluntary command.
00 - Minimum
05 - Maximum
00
WC - Setting of pre-flashing time on closing. [s]
Adjustment of the lead time for the switch-on of the
ashing light, in relation to the start of the closing op-
eration from a voluntary command.
00 - Minimum
05 - Maximum
00
TS - Setting of renewal of automatic closing time af-
ter safety device release. [%]
00 - Minimum
99 - Maximum
99
VR - Setting of learning speed. [cm/s]
05
08
(Neos Super Fast)
i
N.B.: make adjustments gradually and only after performing at least three complete
operations to allow the control panel to be set correctly and detect any friction during
operations.
AP