6. Electrical connections
control panel E1HBOX
To reverse the rotation direction reverse the polarity of the motor phases.
NOTE: the electrical wiring and the start-up of the gearmotors are shown in the control
panel installation manuals.
Before connecting the power supply, make sure that the data on the plate correspond to the elec-
tricity distribution network data. Provide an omnipolar switch/disconnector on the power network
with a contact opening distance of 3 mm or more. Check that there is a suitable residual-current
device and surge protector upstream of the electrical system. Use an H05RN-F 3G1.5 electrical
cable and connect it to terminals L (brown) and N (blue) inside the automation system. Connect
the earth cable
(yellow/green) to the earth terminal.
Secure the cable by means of the cable clamp and only unsheathe it at the terminal.
Connections to the electrical distribution network and any other low-voltage conductors (230 V), in
the section outside the automation system, must be made with corrugated pipes that are independ-
ent and separate from the path of connections to the control and safety devices (SELV = Safety Extra
Low Voltage). Make sure there are no sharp edges that could damage the power cord.
ATTENTION: always observe L-N polarity when connecting to the mains.
Ensure that the mains connection cables, any other low-voltage cables (230 V), and safety
extra-low voltage safety accessory connection cables in the portion located inside the prod-
uct are kept well separated from the gear motor body.
respect L-N
polarity