- Insert the casing [9] and fix it using the supplied
screws.
- Screw the bulb into the bulb support.
- Fix the courtesy light casing [8] using the supplied
screws.
- Drill a hole in the control panel casing for the wiring.
Fix the cable gland fastening bracket.
- Fix the casing [16] to the control panel.
7. Automation closure
8. Routine maintenance plan
Perform the following operations and checks every 6 months according to intensity of use of the
automation.
Without power supply and batteries if present:
- Clean and lubricate the moving parts, using neutral grease.
- Check the stability of the automatic system and make sure that all screws are correctly tightened.
- Check the resistance of the fixing points.
Reconnect the 230 V~ power supply and batteries if present:
- Check the power adjustment.
- Check that all commands and safety functions (photocells) are operating correctly.
- Check the batteries are working (continuously) if present, by removing the power supply and
making a series of operations. Once performed, turn on power supply again.
NOTE: For spare parts, see the spares price list.