Connect the power supply to a certified-compliant omnipolar switch (not included)
with a contact opening distance of at least 3mm. Connection to the mains must
be via an independent conduit, separated from the connections to the command
and safety devices.
1 BOX3EH Gearmotor 3G x 1.5 mm²
2 ZEN Transmitter /
3
AXK4 Digital combination wireless keypad /
AXK5M
AXK5N
AXK5NM
AXK5NI
Wall-mounted key-operated selector switch with European cylinder
Semi-recessed key-operated selector switch with European cylinder
Wall-mounted key-operated selector switch without cylinder
Semi-recessed key-operated selector switch without cylinder
4 x 0.5 mm²
AXR7 RFID reader unit 5 x 0.5 mm²
4
LIN2
LIN2B
AXP2
LAB4
Photocells 4 x 0.5 mm²
5 LAB9 Magnetic loop 2 x 1,5 mm²
6
SOFAP20
SOF2M20-SOF3M20
SOFA15-SOFA20-SOFA25
Safety edge
2 x 0,5 mm²
min
7
FLM
FL24
Flashing light 2 x 1 mm²
Antenna (integrated in the flashing light)
coax cable
RG-58 (50 Ω)
2. Standard installation