5.3 Accessories
Surge Suppressers High voltage (120 V) suppresser: P/N 1878-076.
Phone line suppresser: P/N 1878-077.
Low voltage (28 V) suppresser: P/N 1878-078.
Mounting Post Standard gooseneck mounting post: P/N 1200-045.
Standard gooseneck mounting post – long: P/N 1200-046
Telephone Test Set Includes clips, cord and carrying case. P/N 1800-050.
Battery 12 volt .8 amp hour gel cell provides stand by power during power
interruptions. P/N 1801-008.
SYMPTON POSSIBLE SOLUTION(S)
Four-digit entry codes
will not work.
Forgetting to press # first.
Entry code is time zone restricted. Reprogram time zone or turn time zone off
(5.2.4).
Entry code attempted was a flash code that is no longer valid.
Five-digit entry codes
will not work.
Forgetting to press ## first.
Entry code is time zone restricted. Reprogram time zone or turn time zone off
(5.2.4).
Entry codes will not
activate relay 1.
Programmed entry codes are greater than the divide number. Reprogram
divide number or program entry codes less than the divide number.
Entry codes will not
activate relay 2.
Programmed entry codes are less than or equal to the divide number.
Reprogram divide number or program entry codes greater than the divide
number
System emits a beep
every 30 seconds.
Master code switch is in the ON position.
LCD is unreadable
(1802, 1803, 1810
units only).
Adjust contrast.