Digital Monitoring Products DualCom Programming and Installation Guide
36
Wi‑Fi Signal Strength (Wi‑Fi SIGNAL)
This option provides a way to test the Wi‑Fi connection with the network. Press any select
area to display Wi‑Fi signal strength. The X’s represent the numerical value of the signal
strength in ‑dBm. The
’s represent the signal strength 0‑7.
Wi‑Fi Signal Strength
Number of Bars Indication
7
Good Signal (Excellent for consistent operation)6
5
4
Average Signal (Expect consistent operation)3
2
1 Weak Signal (Will not operate reliably. Relocate Wi‑Fi
equipment or add a Wi‑Fi extender for better reception.)
0 No Signal
Panel Settings
Press a top row key to access the MAC address, serial number, model, and firmware version.
MAC Address
The MAC address uniquely identifes each network node and is different from the IP address, which is assignable. The
MAC address is the panel onboard network hardware address. Press any select area to display the panel MAC address.
Serial Number
This number is the communicator serial number. Reference this number for communicator date‑of‑manufacture and
hardware version. Press any select area to display the serial number.
Model Number
This menu option displays the model number of the communicator.
Firmware Version
This menu option displays the firmware version number and date code of the communicator.
Z‑Wave Test Option (DualComWZ only)
This feature allows the installer to test
communicator
communication with Z‑Wave devices. A
successful test indicates a response from a device. Press any select area to view the Z‑Wave
device list.
Press CMD to advance through each Z‑Wave device and press any select area to begin the
test on the device displayed.
The name of the device displays above the device number. The current number of successful
communications followed by the total number of attempts displays to the right of the device
number. The test stops after 99 attempts.
Press CMD to view the final number of successful communications.
Initializing Z‑Wave Defaults (DualComWZ only)
Only use this function if the ZWave network primary controller is missing or otherwise inoperable.
1. Reset the panel and enter 2313 (DIAG) at the keypad to access the Diagnostic menu.
2. Press CMD until INIT ZWAVE displays. Press a select area.
3. Select YES when Z‑WAVE? NO YES displays. INIT SUCCESSFUL displays when all Z‑Wave programming has
been initialized.
Contact ID Recvd
This displays DTMF digits dialed from the burglary control panel.
Exiting the Diagnostics program
Press CMD until STOP displays. Press any select area. The keypad returns to the status list display.
SIGNAL:
▐▐▐▐▐▐▐
COMNET123
TEST ZWAVE
DEVICE LIST:
HALLWAY LIGHT
HALLWAY LIGHT
LIGHT 02 0/0
HALLWAY LIGHT
99/99
SUCCESSFUL