EN
MCA1215 – MCA2440 Using the device
27
When you have connected the remote control MCA-RC1 (accessory)
Activate or deactivate sleep mode (noise reduced mode) using the “Sleep
Mode” button (fig. 0 2, page 7).
The fan is not regulated in sleep mode.
The LED (fig. 0 1, page 7) on the MCA-RC1 indicates the operating status (see
following table).
I
Mode Display Meaning
Sleep mode activated Orange, constantly lit Phase 1 to 5
Sleep mode
deactivated
Green, slowly
flashing
Phase 1 to 4
Green, constantly lit Phase 5
Fault Red, constantly lit Short circuit or defective fuse
Red, quickly flashing Battery or battery charger is overheating
Red, slowly flashing Battery undervoltage or overload
Red, double flash Fan fault
Red, slow double
flash
Fault at the starter battery connection
NOTE
In the event of a fault (the Status LED is red), refer to chapter “Trouble-
shooting” on page 29).