INSTALLATION INSTRUCTIONS
2-48 EPT031055 Issue 2 September 2017
The shutter option has to be activated in the install options dialogue.
The following components are parts of the safety system:
At the customer’s machine:
Two independent safety switches at the guard door
In the controller:
Safety relay PNOZ mm0p from Pilz (only for shutter option)
Shutter with coil and 2 light barriers (only for shutter option)
Control board with 2 Elesta safety relays
In the D-Series Core Controller:
Safety Relay PNOZ S4 from Pilz with 2 interlock loops
Laser Power Supply